KEY POINTS
Built-in printer Intuitive interface due to icons LED on the probe handle to light dark areas Single connector Interchangeable probe 2 Go memory (100 000 measurements) Step by step procedure menu (gas flow, inspections)FEATURES OF THE INSTRUMENTGAS - Autozero in the flue- CO sensor protection bysolenoid valveFlue gas CO and ambientCO maxInterchangeable sensors: O2 long lifeand CO-H2 and NO and CH4 (optional)Excess airLossesEfficiency > 100%PRESSURE Differential pressuremeasurementDraft measurementTEMPERATURE Ambient temperature Flue gas temperature Delta Temperature DHW temperature2 thermocouplesDew pointtemperatureOTHERFUNCTIONS15 programmed combustibles1 Adding 5 combustibles bythe userOpacity indexCOMBUSTION GAS ANALYSERKIGAZ 210CO-H2, NO and CH4interchangeable sensorsCO sensor protection bysolenoid valveO2 long life sensor1Combustibles: Sahara/Fos-sur-Mer Natural Gas, Groningen Natural Gas, Russia/North Sea Natural Gas, Propane, LPG, Butane, Light Oil, Heavy Oil, Bituminous coal, Hard coal, Coke gas, Bio fuel 5 %,Wood 20 %, Wood-chip 21 %, Pellet 8 %Auto-zeroing in the flueKIGAZ MOBILE ApplicationMEASURING RANGEParameter Sensor Measuring range Resolution Accuracy*T90 responsetimeLong life O2 Electro-chemical From 0 % to 21 % 0.1 % vol. ±0.2 % vol. 30 sCO(with H2 compensation) Electro-chemical From 0 to 8000 ppm 1 ppmFrom 0 to 200 ppm: ±10 ppmFrom 201 to 2000 ppm: ±5% of measured valueFrom 2001 to 8000 ppm: ±10% of measured value30 sNO Electro-chemical From 0 to 5000 ppm 1 ppm From 0 to 100 ppm: ±5 ppm.From 101 to 5000 ppm: ±5% of measured value 30 sLow range NO Electrochemical From 0 to 500 ppm 0.1 ppm From 0 to 100 ppm: ±2 ppmFrom 101 to 500 ppm: ±2 % of the measured value 30 sNOx Calculated** From 0 to 5155 ppm 1 ppm - -CO2 Calculated** From 0 to 99 % vol 0.1 % vol - -CH4 SemiconductorFrom 0 to 10000 ppmFrom 0 to 1 % VolFrom 0 to 20 %LEL1 ppm0.0001 % Vol0.002 %LEL±20 % of full scale 40 sFlue gas temperature K thermocouple From -100 to +1250 °C 0.1 °C ±0.4 % of measured value or ±1.1 °C 45 sAmbient temperature Internal NTC From -20 to +120 °C 0.1 °C ±0.5 °CAmbient temperature Pt100 (1/3 DINexternal probe) From -50 to +250 °C 0.1 °C ±0.3 % of measured value ±0.25 °C 30 sDew pointtemperature Calculated** From 0 to +99 °Ctd 0.1 °C - -DHW temperature TcK (external probe) From -200 to +1300 °C 0.1 °C ±0.4 % of measured value or ±1.1 °C -Differential pressurePiezoelectricFrom -20 000to +20 000 Pa 1 Pa From -20 000 to -751 Pa: ±0.5 % of measured value ±4.5 PaFrom 750 to -61 Pa: ±0.9% of measured value ±1.5 PaFrom -60 to 60 Pa: ±2 PaFrom 61 to 750 Pa: ±0.9% of measured value ±1.5 PaFrom 751 to 20 000 Pa: ±0.5% of measured value ±4.5 Pa-Draft From -10 to +10 PaFrom -1000 to +1000 Pa0.1 Pa1 PaLosses Calculated** From 0 to 100% 0.1% - -Flue gas velocity Calculated** From 0 to 99.9 m/s 0.1 m/s - -Excess air (λ) Calculated** From 1 to 9.99 0.01 - -Efficiency (ηs) Calculated** From 0 to 100 % 0.1 % - -Efficiency (ηt)(condensation) Calculated** From 0 to 120 % 0.1 % - -Opacity index External instrument From 0 to 9 - -*All accuracies indicated in this document were stated in laboratory conditions and can be guaranteed for measurements carried out in the same conditions, or carried out with required compensation.**Calculation is made based on the measured values by the analyzer.
Built-in printer Intuitive interface due to icons LED on the probe handle to light dark areas Single connector Interchangeable probe 2 Go memory (100 000 measurements) Step by step procedure menu (gas flow, inspections)FEATURES OF THE INSTRUMENTGAS - Autozero in the flue- CO sensor protection bysolenoid valveFlue gas CO and ambientCO maxInterchangeable sensors: O2 long lifeand CO-H2 and NO and CH4 (optional)Excess airLossesEfficiency > 100%PRESSURE Differential pressuremeasurementDraft measurementTEMPERATURE Ambient temperature Flue gas temperature Delta Temperature DHW temperature2 thermocouplesDew pointtemperatureOTHERFUNCTIONS15 programmed combustibles1 Adding 5 combustibles bythe userOpacity indexCOMBUSTION GAS ANALYSERKIGAZ 210CO-H2, NO and CH4interchangeable sensorsCO sensor protection bysolenoid valveO2 long life sensor1Combustibles: Sahara/Fos-sur-Mer Natural Gas, Groningen Natural Gas, Russia/North Sea Natural Gas, Propane, LPG, Butane, Light Oil, Heavy Oil, Bituminous coal, Hard coal, Coke gas, Bio fuel 5 %,Wood 20 %, Wood-chip 21 %, Pellet 8 %Auto-zeroing in the flueKIGAZ MOBILE ApplicationMEASURING RANGEParameter Sensor Measuring range Resolution Accuracy*T90 responsetimeLong life O2 Electro-chemical From 0 % to 21 % 0.1 % vol. ±0.2 % vol. 30 sCO(with H2 compensation) Electro-chemical From 0 to 8000 ppm 1 ppmFrom 0 to 200 ppm: ±10 ppmFrom 201 to 2000 ppm: ±5% of measured valueFrom 2001 to 8000 ppm: ±10% of measured value30 sNO Electro-chemical From 0 to 5000 ppm 1 ppm From 0 to 100 ppm: ±5 ppm.From 101 to 5000 ppm: ±5% of measured value 30 sLow range NO Electrochemical From 0 to 500 ppm 0.1 ppm From 0 to 100 ppm: ±2 ppmFrom 101 to 500 ppm: ±2 % of the measured value 30 sNOx Calculated** From 0 to 5155 ppm 1 ppm - -CO2 Calculated** From 0 to 99 % vol 0.1 % vol - -CH4 SemiconductorFrom 0 to 10000 ppmFrom 0 to 1 % VolFrom 0 to 20 %LEL1 ppm0.0001 % Vol0.002 %LEL±20 % of full scale 40 sFlue gas temperature K thermocouple From -100 to +1250 °C 0.1 °C ±0.4 % of measured value or ±1.1 °C 45 sAmbient temperature Internal NTC From -20 to +120 °C 0.1 °C ±0.5 °CAmbient temperature Pt100 (1/3 DINexternal probe) From -50 to +250 °C 0.1 °C ±0.3 % of measured value ±0.25 °C 30 sDew pointtemperature Calculated** From 0 to +99 °Ctd 0.1 °C - -DHW temperature TcK (external probe) From -200 to +1300 °C 0.1 °C ±0.4 % of measured value or ±1.1 °C -Differential pressurePiezoelectricFrom -20 000to +20 000 Pa 1 Pa From -20 000 to -751 Pa: ±0.5 % of measured value ±4.5 PaFrom 750 to -61 Pa: ±0.9% of measured value ±1.5 PaFrom -60 to 60 Pa: ±2 PaFrom 61 to 750 Pa: ±0.9% of measured value ±1.5 PaFrom 751 to 20 000 Pa: ±0.5% of measured value ±4.5 Pa-Draft From -10 to +10 PaFrom -1000 to +1000 Pa0.1 Pa1 PaLosses Calculated** From 0 to 100% 0.1% - -Flue gas velocity Calculated** From 0 to 99.9 m/s 0.1 m/s - -Excess air (λ) Calculated** From 1 to 9.99 0.01 - -Efficiency (ηs) Calculated** From 0 to 100 % 0.1 % - -Efficiency (ηt)(condensation) Calculated** From 0 to 120 % 0.1 % - -Opacity index External instrument From 0 to 9 - -*All accuracies indicated in this document were stated in laboratory conditions and can be guaranteed for measurements carried out in the same conditions, or carried out with required compensation.**Calculation is made based on the measured values by the analyzer.