KEY POINTS
Intuitive graphic interfaceLED on the probe handle to light dark areas Built-in printerAuto-zeroing in the flueFEATURES OF THE INSTRUMENTGAS - Autozeroing in the flue- CO dilution up to 5% 1Flue gases CO and CO2,ambient CO maxInterchangeable sensors: long life O2,COH2, NO, NO2, SO2, CH4 (optional)Excess airLossesEfficiency > 100%PRESSURE Differential pressuremeasurementHigh accuracy draft measurementwith autozero by solenoid valveGas flow auto-settingTEMPERATURE Ambient temperature Flue gas temperature Delta Temperature DHW Temperature2 thermocouplesDew pointtemperatureOTHERFUNCTIONS15 programmedcombustibles2Adding 5 combustiblesby the userOpacity index Single connector Interchangeable probe 2 Go memory (100 000 measurements)CO-H2, NO, NO2, SO2, CH4interchangeable sensorsO2 long life sensorCO dilution2Combustibles: Sahara/Fos-sur-Mer Natural Gas, Groningen Natural Gas, Russia/North Sea Natural Gas, Propane, LPG, Butane, Light Oil, Heavy Oil, Bituminous coal, Hard coal, Coke gas, Bio fuel 5%,Wood 20%, Wood-chip 21%, Pellet 8%1With an accuracy of ±10% of the measurementGas flow auto-setting
Parameters Sensor Measuring range Resolution Accuracy*T90 responsetimeLong life O2 Electrochemical From 0 % to 21 % 0.1 % vol. ±0.2 % vol. 30 sCO(with H2compensation)Electrochemical From 0 to 8000 ppm 1 ppm From 0 to 200 ppm: ±10 ppmFrom 201 to 2000 ppm: ±5 % of the measured valueFrom 2001 to 8000 ppm: ±10 % of the measured value30 sNO Electrochemical From 0 to 5000 ppm 1 ppm From 0 to 100 ppm: ±5 ppm.From 101 to 5000 ppm: ±5 % of the measured value30 sLow range NO Electrochemical From 0 to 500 ppm 0.1 ppm From 0 to 100 ppm: ±2 ppmFrom 101 to 500 ppm: ±2 % of the measured value30 sNOx Calculated** From 0 to 5155 ppm 1 ppm - -NO2 Electrochemical From 0 to 1000 ppm 1 ppm From 0 to 100 ppm: ±5 ppm.From 101 to 1000 ppm: ±5 % of the measured value80 sSO2 Electrochemical From 0 to 5000 ppm 1 ppm From 0 to 100 ppm: ±5 ppm.From 101 to 5000 ppm: ±5 % of the measured value80 sCO2 Calculated** From 0 to 99 % vol 0.1% vol - -CH4 Semiconductor From 0 to 10000 ppmFrom 0 to 1 % VolFrom 0 to 20 %LEL1 ppm0.0001 % Vol0.002 %LEL±20 % of full scale 40 sFlue gas temperature K thermocouple From -100 to +1250 °C 0.1 °C ±0.4 % of the measured value or ±1.1 °C 45 sAmbient temperature Internal NTC From -20 to +120 °C 0.1 °C ±0.5 °CAmbient temperature Pt100 (1/3 DINexternal probe)From -50 to +250 °C 0.1 °C ±0.3 % of the measured value ±0.25 °C 30 sDew pointtemperatureCalculated** From 0 to +99 °Ctd 0.1 °C - -DHW temperature TcK (external probe) From -200 to +1300 °C 0.1 °C ±0.4 % of the measured value or ±1.1 °C -Draft Piezoelectric From -10 to +10 PaFrom -1000 to +1000 Pa0.1 Pa1 PaFrom -100 to -10 Pa: ±2 PaFrom -10 to +10 Pa: ±0.5 PaFrom +10 to +100 Pa: ±2 PaAbove: ±2 % of the measured value-Differential pressure Piezoelectric From -20 000to +20 000 Pa1 Pa From -20 000 to -751 Pa: ±0.5 % of the measured value ±4.5 PaFrom 750 to -61 Pa: ±0.9 % of the measured value ±1.5 PaFrom -60 to 60 Pa: ±2 PaFrom 61 to 750 Pa: ±0.9 % of the measured value ±1.5 PaFrom 751 to 20 000 Pa: ±0.5 % of the measured value ±4.5 Pa-Losses Calculated** From to 100% 0.1% - -Flue gas velocity Calculated** From to 99.9 m/s 0.1 m/s - -Excess air (λ) Calculated** From 1 to 9.99 0.01 - -Lower efficiency (ηs) Calculated** From 0 to 100% 0.1 % - -Higher efficiency (ηt)(condensation)Calculated** From 0 to 120% 0.1% - -Opacity index External instrument From 0 to 9 - - -
Intuitive graphic interfaceLED on the probe handle to light dark areas Built-in printerAuto-zeroing in the flueFEATURES OF THE INSTRUMENTGAS - Autozeroing in the flue- CO dilution up to 5% 1Flue gases CO and CO2,ambient CO maxInterchangeable sensors: long life O2,COH2, NO, NO2, SO2, CH4 (optional)Excess airLossesEfficiency > 100%PRESSURE Differential pressuremeasurementHigh accuracy draft measurementwith autozero by solenoid valveGas flow auto-settingTEMPERATURE Ambient temperature Flue gas temperature Delta Temperature DHW Temperature2 thermocouplesDew pointtemperatureOTHERFUNCTIONS15 programmedcombustibles2Adding 5 combustiblesby the userOpacity index Single connector Interchangeable probe 2 Go memory (100 000 measurements)CO-H2, NO, NO2, SO2, CH4interchangeable sensorsO2 long life sensorCO dilution2Combustibles: Sahara/Fos-sur-Mer Natural Gas, Groningen Natural Gas, Russia/North Sea Natural Gas, Propane, LPG, Butane, Light Oil, Heavy Oil, Bituminous coal, Hard coal, Coke gas, Bio fuel 5%,Wood 20%, Wood-chip 21%, Pellet 8%1With an accuracy of ±10% of the measurementGas flow auto-setting
Parameters Sensor Measuring range Resolution Accuracy*T90 responsetimeLong life O2 Electrochemical From 0 % to 21 % 0.1 % vol. ±0.2 % vol. 30 sCO(with H2compensation)Electrochemical From 0 to 8000 ppm 1 ppm From 0 to 200 ppm: ±10 ppmFrom 201 to 2000 ppm: ±5 % of the measured valueFrom 2001 to 8000 ppm: ±10 % of the measured value30 sNO Electrochemical From 0 to 5000 ppm 1 ppm From 0 to 100 ppm: ±5 ppm.From 101 to 5000 ppm: ±5 % of the measured value30 sLow range NO Electrochemical From 0 to 500 ppm 0.1 ppm From 0 to 100 ppm: ±2 ppmFrom 101 to 500 ppm: ±2 % of the measured value30 sNOx Calculated** From 0 to 5155 ppm 1 ppm - -NO2 Electrochemical From 0 to 1000 ppm 1 ppm From 0 to 100 ppm: ±5 ppm.From 101 to 1000 ppm: ±5 % of the measured value80 sSO2 Electrochemical From 0 to 5000 ppm 1 ppm From 0 to 100 ppm: ±5 ppm.From 101 to 5000 ppm: ±5 % of the measured value80 sCO2 Calculated** From 0 to 99 % vol 0.1% vol - -CH4 Semiconductor From 0 to 10000 ppmFrom 0 to 1 % VolFrom 0 to 20 %LEL1 ppm0.0001 % Vol0.002 %LEL±20 % of full scale 40 sFlue gas temperature K thermocouple From -100 to +1250 °C 0.1 °C ±0.4 % of the measured value or ±1.1 °C 45 sAmbient temperature Internal NTC From -20 to +120 °C 0.1 °C ±0.5 °CAmbient temperature Pt100 (1/3 DINexternal probe)From -50 to +250 °C 0.1 °C ±0.3 % of the measured value ±0.25 °C 30 sDew pointtemperatureCalculated** From 0 to +99 °Ctd 0.1 °C - -DHW temperature TcK (external probe) From -200 to +1300 °C 0.1 °C ±0.4 % of the measured value or ±1.1 °C -Draft Piezoelectric From -10 to +10 PaFrom -1000 to +1000 Pa0.1 Pa1 PaFrom -100 to -10 Pa: ±2 PaFrom -10 to +10 Pa: ±0.5 PaFrom +10 to +100 Pa: ±2 PaAbove: ±2 % of the measured value-Differential pressure Piezoelectric From -20 000to +20 000 Pa1 Pa From -20 000 to -751 Pa: ±0.5 % of the measured value ±4.5 PaFrom 750 to -61 Pa: ±0.9 % of the measured value ±1.5 PaFrom -60 to 60 Pa: ±2 PaFrom 61 to 750 Pa: ±0.9 % of the measured value ±1.5 PaFrom 751 to 20 000 Pa: ±0.5 % of the measured value ±4.5 Pa-Losses Calculated** From to 100% 0.1% - -Flue gas velocity Calculated** From to 99.9 m/s 0.1 m/s - -Excess air (λ) Calculated** From 1 to 9.99 0.01 - -Lower efficiency (ηs) Calculated** From 0 to 100% 0.1 % - -Higher efficiency (ηt)(condensation)Calculated** From 0 to 120% 0.1% - -Opacity index External instrument From 0 to 9 - - -