Flat Plate Solar Water Heater by Easy Photovoltech Private Limited

We provide the Flat Plate Solar Water Heater to the clients.SOLAR THERMAL WATER HEATER:There are two types of solar water heating systems, based on type of circulation; 1. Thermosyphon 2. Forced ..

Categories: ,

Product Description

We provide the Flat Plate Solar Water Heater to the clients.

SOLAR THERMAL WATER HEATER:

There are two types of solar water heating systems, based on type of circulation;

1. Thermosyphon 2. Forced circulation

All domestic and industrial systems up to 4000 LPD (litres per day) @ 60 deg.C,; works on the principle of thermosyphon. Industrial systems beyond 4000 LPD to any capacity will work on forced circulation principle.

Thermosyphon system:
The system works on a principle called "THERMOSYPHON" (Natural circulation). Due to the density difference between the cold & hot Water, the lighter hot water flows up into the tank and the heavier cold water enters the collector.

Solar radiation incident on the collector panels heats the absorber. This heat is transferred to the water contained in the absorber & becomes less dense than the water in the storage tank. Hot water starts rising and settles at the top of the storage tank. Simultaneously cold water descends to the collector absorber tubes, gets heated up and the cycle repeats.

The circulation in the system during the heating process is purely due to the difference of density only. There is no other mechanical moving part, hence the system reliability is very high.

At the end of the day when radiation is zero (after dark/sun set), the collector will contain heavier cold water and the tank will have lighter hot water. This will ensure that there will be no circulation during the night & hence no conduction losses on account of this.

The hot water storage tank is well insulated to retain the hot water temperature and to minimise the overnight temperature drop/heat losses.

The Sacrificial Anode (Only for SS tank) prevents the tank from galvanic corrosion. For the monsoon / cloudy days, the system is fitted with an Electrical backup heater with thermostat.

Forced circulation system:
In forced circulation systems, two pumps in tandem are used for circulation of water between collector bank & system insulated tank. The pump operation is controlled by OTC (Differential Temperature Controller), which is fitted Inside the Control panel. OTC senses the cold & hot water temperature through two sensors, one fitted at the bottom of the tank to sense cold water temperature & the other fitted at the top of the last collector of the row in the collector bank, to sense the hot water temperature inside the collector

The difference in temperature between the two sensor points is the criteria for the operation of the pump that is controlled through DTC. This temperature difference can be set between 0 to 10 deg, C.

Solar radiation falling on the collector heats up the water inside the absorber. The temperature of water starts gradually increasing compared to the water temperature inside the tank. When this temperature difference between the sensor points reaches the preset temperature difference in DTC, the pump is switched "ON". This will result in the entry of cold water from the system-insulated tank into the collector bank & discharge of hot water from the collector bank to the system insulated tank.

The sensor fitted at the collector will sense the temperature of cold water entering into the collector & puts "OFF" the pump when this temperature difference between the sensor points falls below the preset temperature difference in DTC.

The process of switching ON & QFF of the pump & circulation of water continues until the end of the day. By the end of the day, the entire quantity of water in the tank reaches the system designed temperature, provided the radiation level is at a minimum of 800 watts per sq.mtr.

Product Specification

Similar Products

New
Evacuated Tube Domestic Solar Water Heater
Focusun Energy Systems from Coimbatore

We are one of the leading manufacturers of Evacuated Tube Domestic Solar Water Heater, contact us fo.

New
Flat Plate Commercial Solar Water Heater
Focusun Energy Systems from Coimbatore

The solar hot water system is based on the principle of back body absorption. The black surface of t.

New
Evacuated Tube Commercial Solar Water Heater
Focusun Energy Systems from Coimbatore

Evacuated tubes are the absorber of the solar water heater. They absorb solar energy converting it i.

New
Energy Solar Water Heater for Textile Industry
Focusun Energy Systems from Coimbatore

Being one of the market leaders in manufacturing and supplying this commendable Energy Solar Water H.

New
Haier Solar Water Heater
Shree Solar Tech from Pune

Non Mixing Technology Helps To Full Usage Of Hot Water At Any Time.No Need To Installed Overhead Tan.

New
Solar Water Heater
Mharatna Engineering Corporation from Jabalpur

The system works to the thermosiphon principle, meaning that heat is transferred entierly by me.

New
Solar Water Heater
Mharatna Engineering Corporation from Jabalpur

Keeping in sync with the latest fashion trends, we are engaged in providing a trendy array of Pre He.

New
Solar Water Heater Storage Tank
Goodsun Industries Pvt. Ltd. from Coimbatore

We are listed amongst the faithful entities in this domain by offering a superior quality array of S.

New
Services Of Solar Water Heater
Energy Saving Corporation from Mohali

With our profound vision to make our clientele satisfied, we have introduced Services Of Solar Water.

New
ETC Solar Water Heater
Jainsons Electronics from Delhi

We have carved a niche amongst the most trusted names in this business, engaged in offering a compre.

New
Flat Plate Collector Solar Water Heater
Jainsons Electronics from Delhi

In order to keep pace with the never-ending demands of customers, we are involved in offering a wide.

Submit your review