It is used for the determination of the consistency of freshly mixed concrete, where the maximum size of the aggregate does not exceed 38mm.

Specification : The apparatus consists of one slump cone with handles and foot pieces. The slump cone has internal dimension 20 cm dia at base 10 cm top dia and 30 cm height foot pieces can be fixed to the clamps on the base plate. The base plate has lifting handle for easy transportation . One graduated steel rod 16mm dia x 600mm long Rounded at both ends and graduated in mm is also supplied.

Reporting of Results
The slump measured should be recorded in mm of subsidence of the specimen during the test. Any slump specimen, which collapses or shears off laterally gives incorrect result and if this occurs, the test should be repeated with another sample. If, in the repeat test also, the specimen shears, the slump should be measured and the fact that the specimen sheared, should be recorded.

 

1. What is the ideal value of slump?
Answer 1
 In case of a dry sample, slump will be in the range of 25-50 mm that is 1-2 inches. But in case of a wet concrete, the slump may vary from 150-175 mm or say 6-7 inches. So the value of slump is specifically mentioned along the mix design and thus it should be checked as per your location.

Slump depends on many factors like properties of concrete ingredients – aggregates etc. Also temperature has its effect on slump value. So all these parameters should be kept in mind when deciding the ideal slump

How does a super plasticizer effect the slump of concrete?
Answer 2 
Value of Slump can be increased by the addition of chemical admixtures like mid-range or high-range water reducing agents (super-plasticizers) without changing the water/cement ratio.

How much time one should take to raise the cone?
Answer 3 Once the cone is filled and topped off [excessive concrete from top is cleared] raise the cone within 5-10 seconds.

Product Specification

Similar Products

New
Silicone Pump
Shree Gopal Traders from Bhilwara

Kirloskar Sct Pumps.

New
Single Cone Vacuum Pumps
Ppi Pumps Pvt. Ltd. from Ahmedabad

Single Cone Vacuum Pumps .

New
Road Safety Cone
Kamakshi Infotech Enterprises from Bhubaneswar

We are engaged in providing a wide range of Road Safety Cone to our clients.Features:Flawless finish.

New
New
Sockets & Cones Single
Edutek Instrumentation from Ambala

Socket & Cones SingleItem code: 001CS Cat. No. Socket Size Approx. O.D. of Minimum Shank tube .

New
Cones with Tip Single
Edutek Instrumentation from Ambala

Cones with tip SingleItem code: 001CCat. No. Socket Size Approx. O.D. of Minimum Shank tube mm. Leng.

Submit your review